Voltage Irregularity Report

Brieske residence, Orcutt CA · Last 3 days · Thu Nov 19, 8:11 AM to Sun Nov 22, 8:11 AM · generated 2026-11-22 08:11:40 PST

Since PG&E's monitor went up24 hours3 days7 days14 days30 daysAll time

leave “to” blank for “up to now”

☰ Simple one-page versionDownload .txtDownload .csvPrint / save PDF

Measurement method: three TP-Link EP25 metering outlets record true-RMS line voltage once per second on both 120 V legs of the split-phase service. A Tesla Wall Connector supplies the 240 V line-to-line reference and grid frequency, which is independent of the neutral. A Ting (Whisker) sensor on Leg A samples far faster than 1 Hz and retains the lowest and highest voltage it sees, so it resolves brief excursions that a 1 s RMS average necessarily flattens in both directions. Where the two disagree, the Ting figure is the closer estimate of the real extreme. What is listed: any reading below 114 V (the ANSI C84.1 Range A lower limit) and any reading above 127 V (the Range B upper limit) at 120 V nominal. Undervoltage dims and stalls equipment; sustained overvoltage damages it, so both are reported.

13,487 samples logged today across 147 retained detail files.

Irregularities listed
0
Low / high
0 / 0
Corroborated by Ting
0
Time out of range
under 1 s

Irregularities (newest first)

Nothing left the reported envelope in this window.
Labels describe the simultaneous meter pattern. They do not assert a confirmed physical cause; that determination belongs to the utility or electrician after inspecting the service.