Voltage Irregularities
Brieske residence, Orcutt CA
Mon Aug 17, 1:00 PM to Wed Sep 23, 9:40 AM
Download .txtDownload .csvPrint / save PDFFull detail →
Friday, August 21, 2026
| 10:14:44 AM | LOW | 97.7 V † | 5 s |
| 4:28:51 PM | LOW | 86.3 V † | 5 s |
| 4:29:02 PM | LOW | 86.3 V † | 18 s |
| 4:51:39 PM | LOW | 106.8 V † | 2 s |
| 5:19:49 PM | LOW | 103.5 V † | 11 s |
| 7:50:57 PM | LOW | 106.2 V † | 2 s |
| 7:51:42 PM | LOW | 106.0 V | 2 s |
Saturday, August 22, 2026
| 9:41:20 PM | LOW | 105.7 V † | 2 s |
| 10:28:30 PM | LOW | 106.1 V † | 2 s |
| 11:01:30 PM | LOW | 112.0 V | 2 s |
| 11:02:00 PM | LOW | 108.6 V | 2 s |
Sunday, August 23, 2026
| 1:52:44 AM | LOW | 107.0 V | 2 s |
| 2:20:21 AM | LOW | 106.1 V † | 11 s |
| 7:34:13 AM | LOW | 107.2 V † | 2 s |
| 3:04:33 PM | LOW | 106.1 V † | 2 s |
| 3:24:40 PM | LOW | 105.2 V † | 2 s |
| 4:31:26 PM | LOW | 84.8 V † | 17 s |
Tuesday, September 1, 2026
| 9:14:49 PM | LOW | 114.0 V | 7 s |
| 9:15:16 PM | LOW | 113.2 V | 2 min 45 s |
Wednesday, September 23, 2026
| 12:00:22 AM | LOW | 113.8 V | 3 s |
20 in this window · 20 low (lowest 84.8 V) · 4 min 24 s out of range
Also recorded but not listed individually: 32 brief high readings on a 120 V branch meter, peaking at 127.4 V. These are held back for two reasons: readings between 126 V and 127 V are inside ANSI Range B, which the standard tolerates as occasional; and none of them were confirmed by the neutral-independent 240 V line-to-line reference, which never left its limits. They are reported as a count so that nothing is hidden, not because they are being claimed.
† measured by the Ting sensor, which samples faster than once per second and therefore resolves brief excursions the 1 s branch meters average away.
LOW = below 114 V. Normal service is 114–126 V (ANSI C84.1 Range A) at 120 V nominal. A HIGH row appears only when the neutral-independent 240 V line-to-line reference also left its limits.