Voltage Irregularities
Brieske residence, Orcutt CA
Mon Aug 24, 11:00 AM to Wed Sep 23, 11:00 AM
Download .txtDownload .csvPrint / save PDFFull detail →
Tuesday, September 1, 2026
| 9:14:49 PM | LOW | 114.0 V | 7 s |
| 9:15:16 PM | LOW | 113.2 V | 2 min 45 s |
Wednesday, September 23, 2026
| 12:00:22 AM | LOW | 113.8 V | 3 s |
3 in this window · 3 low (lowest 113.2 V) · 2 min 55 s out of range
Also recorded but not listed individually: 5 brief high readings on a 120 V branch meter, peaking at 126.7 V. These are held back for two reasons: readings between 126 V and 127 V are inside ANSI Range B, which the standard tolerates as occasional; and none of them were confirmed by the neutral-independent 240 V line-to-line reference, which never left its limits. They are reported as a count so that nothing is hidden, not because they are being claimed.
† measured by the Ting sensor, which samples faster than once per second and therefore resolves brief excursions the 1 s branch meters average away.
LOW = below 114 V. Normal service is 114–126 V (ANSI C84.1 Range A) at 120 V nominal. A HIGH row appears only when the neutral-independent 240 V line-to-line reference also left its limits.